Sign In | Join Free | My chinacsw.com |
|
Brand Name : Yaskawa
Model Number : UTSIH-B17CC
Place of Origin : Japan
MOQ : 1
Price : negotiable
Payment Terms : TT West Union
Supply Ability : 100
Delivery Time : 2-3 work days
Packaging Details : New in original box
Brand : Yaskawa
Model : UTSIH-B17CC
Series : UT series
Resolution : 17 bit
Name of series : CC
YASKAWA ELECTRIC UTSIH-B17CC Internal ENCODER For SGMGH-09ACA61 SERVO MOTOR
QUICK DETAILS
DESCRIPTION
Internal encoders
Specifications
Manufacturer: Yaskawa
Product number: UTSIH-B17CC
Vendor number: B030M0107-1C-SMX
Description: UTSIH-B17CC is an Internal encoders manufactured by Yaskawa
Series: UT series Encoders for AC Servo and Spindle motors
Type: Incremental Encoder
Construction of encoder: Coupled with plate spring for motor (complete)
Resolution: 17 bit
Name of series: CC
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Preventing Noise Interference
Take the following steps to prevent erroneous operation caused by noise interference:
• Use shielded wire for the PG encoder signal lines.
• Limit the length of all motor output power cables to less than 20 m.
• The signal “Sensor Up” must be connected to terminal IP on the PG-F3 option for cables longer than 10 m. Additionally, the “Sensor 0 V”must be connected to terminal IG.
• Use separate conduit or cable tray dividers to separate option control wiring, main circuit input power wiring, and motor output power cables.
• Ground the shield on the PG encoder side and the drive side. If electrical inteference problems arise in the PG encoder signal, verify that the shield is properly grounded and ground one end of the signal line or remove the ground connection on both ends.
• Properly connect the shield in cable to the IG on the option terminal or remove the ground connection on both ends.
Digital Operator Display Fault Name oPE02 Parameter Range Setting Error
Use U1-18 to find parameters set outside range.
Cause Possible Solution
Parameters were set outside the possible range.
Set parameters to the proper values.
Note: When multiple errors occur simultaneously, other errors are given precedence over oPE02.
Digital Operator Display Fault Name
oPE06
Control Method Selection Error
Correct the setting for the control method.
Cause Possible Solution
Control mode requires installinga PG option, but no PG option is installed (A1-02 = 7).
Connect a PG option.
![]() |